SAS PHY state degradation on DS212-12 shelves
Applies to
- DS212-12 shelves
- ONTAP 9
- NetApp storage systems with SAS connections
Issue
- SAS
PHY stateon DS212-12 shelves have degraded from12.0 Gb/sto6.0 Gb/sobserved on slot 0 ports both 0b and 4c.
sysconfig -a output:
slot 0: SAS Host Adapter 0b (Broadcom SAS3616W rev. 2, SAS, <UP>)
Firmware rev: 12.00.00.00
NVDATA rev: 12.03.01.03
Base WWN: 5:XXXXXX:XXXXXXX:e6
Temperature: Not Available
Phy State: [0] Enabled, 12.0 Gb/s
[1] Enabled, 12.0 Gb/s
[2] Enabled, 12.0 Gb/s
[3] Enabled, 6.0 Gb/s
Mini-SAS HD Vendor: MOLEX
Mini-SAS HD Part Number: 112-00453+A0
Mini-SAS HD Type: Optical (850nm VCSEL) 15m end_1
Mini-SAS HD Serial Number: 93XXXXXXXXXX29-A
Shelf 30: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 31: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 32: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 33: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 34: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 35: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 36: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 37: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
slot 4: SAS Host Adapter 4c (PMC-Sierra PM8072 rev. C, SAS, <UP>)
MFG Part Number: Microsemi Corp. 110-03801 rev. A0
Part number: 111-03801+A0
Serial number: 0BXXXXXXXF4
Date Code: 20200921
Firmware rev: 03.08.09.00
Base WWN: 5:XXXXXX:XXXXXXX:08
Temperature: 44 C
Phy State: [0] Enabled, 12.0 Gb/s
[1] Enabled, 12.0 Gb/s
[2] Enabled, 12.0 Gb/s
[3] Enabled, 6.0 Gb/s
Mini-SAS HD Vendor: Amphenol
Mini-SAS HD Part Number: 112-00453+A0
Mini-SAS HD Type: Optical (850nm VCSEL) 15m ID:00
Mini-SAS HD Serial Number: APXXXXXXXXXX38
Shelf 30: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 31: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 32: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 33: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 34: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 35: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 36: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
Shelf 37: DS212-12 Firmware rev. IOM12B A: 0130 IOM12B B: 0130
SAS-EXPANDER-PHY-STATEoutput indicates PHY 11 on shelf 37 has degraded to 6.0 Gb/s.
Expander phy state on 0b.37 (NETAPP :DS21212IOM12 SHXXXXXXXXXXXXX95):
Pwr Invald Disprt Loss Phy CRC Phy
Pwr Ccl Rsv Rls DWord Error Sync Reset Error Change SATA
PHY/BAY STATE ON Cnt Cnt Cnt Count Count Count Prob Cnt Cnt Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
0/P0:0 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
1/P0:1 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
2/P0:2 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
3/P0:3 12.0 Gb/s --- --- --- --- 0 0 0 0 0 1 ----------------
4/P1:0 Disabled
5/P1:1 Disabled
6/P1:2 Disabled
7/P1:3 Disabled
8/P2:0 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------
9/P2:1 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------
10/P2:2 12.0 Gb/s --- --- --- --- 0 0 0 0 0 13 ----------------
11/P2:3 6.0 Gb/s --- --- --- --- 1 1 0 0 0 13 ----------------