Repetitve disk failures after ONTAP upgrade
Applies to
- ONTAP 9
- Disk Qualification Package (DQP)
- Repetitive disk failures
Issue
- Repetitive disk failure events reported on the cluster
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 10, Bay 10, Model [X343_SSKBE1T8A10], S/N [W+++++GS]
config_thread: callhome.sdsk.fault:error]: Call home for SPARE DISK FAILED Shelf 10, Bay 10, Model [X343_SSKBE1T8A10], S/N [W+++++RG] <==== Same bay, after replacement
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 19, Bay 19, Model [X343_SSKBE1T8A10], S/N [W+++++AW]
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 12, Bay 20, Model [X343_SSKBE1T8A10], S/N [W+++++QQ]
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 13, Bay 4, Model [X343_SSKBE1T8A10], S/N [W+++++XK]
config_thread: callhome.sdsk.fault:error]: Call home for SPARE DISK FAILED Shelf 10, Bay 10, Model [X343_SSKBE1T8A10], S/N [W+++++QF] <====== Failed again
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 11, Bay 11, Model [X343_SSKBE1T8A10], S/N [W+++++L4]
config_thread: callhome.sdsk.fault:error]: Call home for SPARE DISK FAILED Shelf 13, Bay 4, Model [X343_SSKBE1T8A10], S/N [W+++++MM] <==== Same bay, after replacement
config_thread: callhome.fdsk.fault:error]: Call home for FILESYSTEM DISK FAILED Shelf 17, Bay 8, Model [X343_SSKBE1T8A10], S/N [W+++++DC] - Disk firmwares were upgraded as its bundled with ONTAP upgrade.
- After replacement the same disk may fail again in a day or two.
- Some disks may still report failed even after replacement.