Repeated PSU sensor "Unreadable" events due to mainboard failure
Applies to
- AFF-A400
- ONTAP 9.13.1
Issue
- Repeated PSU fault events are observed despite prior replacement of the PSU and Service Processor firmware upgrades.
- The EMS logs show sensor values for PSU1 as unreadable, followed by recovery messages:
Example:
[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 VOUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 CurrIIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 IOUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 PIN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 POUT is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FAN is Unreadable[Node02:env_mgr:monitor.chassisPowerSupply.ok:info]: Chassis power supply 1 is OK.