Remote disks missing some paths after fabric event

Views:
116
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

Applies to

  • Fabric Metrocluster
  • Cisco MDS switches

Issue

  • After a fabric event, some remote disks are missing 4 of the 8 expected paths despite the links being up and functioning:

storage array disk paths show -disk 1.1.1
Disk Name: 1.1.1
UID:
AAAAAAA:BBBBB:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
LUN
Link Disk I/O
Controller Initiator ID Acc Use
Target Port TPGN Speed (KB/s) IOPS
node1 2c 1019 AO INU 2200001086acbb40
1 16 Gb/S 0 0
node1 2a 1019 AO RDY 2100001086acbb40 0
16 Gb/S 0 0
node2 2c 1019 AO RDY 2200001086acbb40 1 16 Gb/S
0 0
node2 2a 1019 AO INU 2100001086acbb40 0 16 Gb/S 124
0

  • Notice the path on 11a and 11c is missing in the above output.
  • The non-affected disks show the correct number of paths:

storage array disk paths show -disk 2.2.1
Disk Name: 2.2.1
UID: CCCCCCC:DDDDDDD:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
LUN Target Side Initiator Side Link Disk I/O
Controller Initiator ID Acc Use Target Port Switch Port Switch Port TPGN Speed (KB/s) IOPS
node1 2c 14 AO RDY 2200001086ab5d80 sw2:1-14 sw2:1-2 30 16 Gb/S 0 0
node1 11c 14 AO RDY 2200001086ab5d40 sw2:1-15 sw2:1-3 26 16 Gb/S 0 0
node1 2a 14 AO RDY 2100001086ab5d80 sw1:1-14 sw1:1-2 29 16 Gb/S 0 0
node1 11a 14 AO INU 2100001086ab5d40 sw1:1-15 sw1:1-3 25 16 Gb/S 0 0
node2 2c 14 AO INU 2200001086ab5d80 sw2:1-14 sw2:1-5 30 16 Gb/S 0 0
node2 11c 14 AO RDY 2200001086ab5d40 sw2:1-15 sw2:1-6 26 16 Gb/S 0 0
node2 2a 14 AO RDY 2100001086ab5d80 sw1:1-14 sw1:1-5 29 16 Gb/S 0 0
node2 11a 14 AO RDY 2100001086ab5d40 sw1:1-15 sw1:1-6 25 16 Gb/S 0 0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.