PriPortToBPort_Alert and SecPortToAPort_Alert reported
Applies to
- ONTAP 9
- AFF/FAS
- NS224 Disk shelves
Issue
- The following alerts are reported in the event logs:
[Node-02: nchmd: hm.alert.raised:alert]: Alert Id = PriPortToBPort_Alert , Alerting Resource = e0e raised by monitor node-connect
[Node-02: nchmd: hm.alert.raised:alert]: Alert Id = SecPortToAPort_Alert , Alerting Resource = e0b raised by monitor node-connect
- system health subsystem show reports degraded
::> system health subsystem show Subsystem Health ----------------- ------------------ SAS-connect degraded Environment ok Memory ok Service-Processor ok Switch-Health ok CIFS-NDO ok Motherboard ok IO ok MetroCluster ok MetroCluster_Node ok FHM-Switch ok FHM-Bridge ok SAS-connect_Cluster ok
- All the nodes are in "Multi-Path HA" configuration:
::> system node run -node * sysconfig -a
NetApp Release 9.8P7: Tue Sep 14 14:42:02 EDT 2021
System ID: 056XXXXXXXX (Node-02); partner ID: 053XXXXXXX (Node-01)
System Serial Number: 6XXXXXX000023 (Node-02)
System Rev: B0
System Storage Configuration: Multi-Path HA
System ACP Connectivity: Inband Active