- BMC event report PSU error:
Record 378: Thu May 28 00:09:14.386513 2026 [IPMI.notice]: 0106 | 02 | EVT: 6f02ffff | PSU2_Status | Assertion Event, "Attention"
Record 379: Thu May 28 00:09:14.440190 2026 [IPMI.notice]: 0107 | 02 | EVT: ef03ffff | PSU2_Status | Deassertion Event, "OUTPUT OK"
Record 380: Thu May 28 00:09:26.161900 2026 [IPMI.notice]: 0108 | 02 | EVT: 6f02ffff | PCM_Status | Assertion Event, "Fault"
Record 381: Thu May 28 00:09:50.672406 2026 [BMC.warning]: PSU2 status word assert: 0x0841
Record 382: Thu May 28 00:09:59.581387 2026 [IPMI.notice]: 0109 | 02 | EVT: 0301ffff | PSU2_Fault_Sum | Assertion Event, "State Asserted"
Record 383: Thu May 28 00:10:03.018882 2026 [IPMI.notice]: 010a | 02 | EVT: 015000ba | PSU2_12V_VOUT | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 11.160
Record 384: Thu May 28 00:10:03.371120 2026 [IPMI.notice]: 010b | 02 | EVT: 01500000 | PSU2_12V_IOUT | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.000
Record 385: Thu May 28 00:10:11.702553 2026 [IPMI.notice]: 010c | 02 | EVT: 015200b0 | PSU2_12V_VOUT | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 10.560
Record 386: Thu May 28 00:10:11.900306 2026 [IPMI.notice]: 010d | 02 | EVT: 01520000 | PSU2_12V_IOUT | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000
Record 387: Thu May 28 00:10:29.679407 2026 [IPMI.notice]: 010e | 02 | EVT: 01500000 | PSU2_IIN | Assertion Event, "Lower Non-critical going low " | Reading: 0.000 | Threshold: 0.000
Record 388: Thu May 28 00:10:38.712746 2026 [IPMI.notice]: 010f | 02 | EVT: 01520000 | PSU2_IIN | Assertion Event, "Lower Critical going low " | Reading: 0.000 | Threshold: 0.000
- ONTAP reports
CriticalFruMultiFaultAlert - ONTAP triggers AutoSupport for
CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 2 - BMC reboot doesn't resolve the issue.