Skip to main content
NetApp Knowledge Base

System fault LED light on and P3V3_BATT sensor error reports repeatedly

Views:
4,467
Visibility:
Public
Votes:
4
Category:
fas-systems
Specialty:
hw
Last Updated:
3/25/2024, 9:35:34 AM

Applies to

  • FAS2520
  • FAS27XX
  • AFF-C190
  • AFF-A220
  • AFF-A700

Issue

  • System Fault LED light on.
  • P3V3_BATT error event can be found in the following command output.

cluster::> system controller service-event show

Node             ID  Event Location                      Event Description
---------------- --- ----------------------------------  ----------------------
node     1   Controller B on Chassis 1           P3V3_BATT: Voltage Sensor 26 UNC

  • BMC "system fru led show all" shows Fault LED is set on by BMC.

BMC node> priv set diag
BMC node*> system fru led show all
FRU LED ID 1 is off
FRU LED ID 2 is on. Set by BMC
FRU LED ID 3 is on
FRU LED ID 4 is on

  • P3V3_BATT sensor error reports repeatedly in the BMC "events all" output.
Record 903: Wed Mar 18 01:52:39.930000 2020 [IPMI.notice]: 0100 | 02 | EVT: 8157bbbd | P3V3_BATT | Deassertion Event, "Upper Non-critical going high" | Reading: 3.272 | Threshold: 3.307
Record 904: Wed Mar 18 02:14:02.350000 2020 [IPMI.notice]: 0001 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
Record 905: Wed Mar 18 04:22:52.940000 2020 [IPMI.notice]: 0002 | 02 | EVT: 8157bbbd | P3V3_BATT | Deassertion Event, "Upper Non-critical going high" | Reading: 3.272 | Threshold: 3.307
Record 906: Wed Mar 18 04:44:27.430000 2020 [IPMI.notice]: 0003 | 02 | EVT: 0157bdbd | P3V3_BATT | Assertion Event, "Upper Non-critical going high" | Reading: 3.307 | Threshold: 3.307
 
Or
 
Record 1945: Sun May 29 23:44:05 2022 [IPMI.notice]: 6401 | 02 | EVT: 8150bfbd | Bat_3.0V | Deassertion Event, "Lower Non-critical going low "
Record 1946: Sun May 29 23:44:14 2022 [IPMI.notice]: 6501 | 02 | EVT: 0150bdbd | Bat_3.0V | Assertion Event, "Lower Non-critical going low "
Record 1947: Sun May 29 23:44:16 2022 [IPMI.notice]: 6601 | 02 | EVT: 0301ffff | Controller_Fault | Assertion Event, "State Asserted"
Record 1948: Mon May 30 00:43:26 2022 [IPMI.notice]: 6701 | 02 | EVT: 0300ffff | Controller_Fault | Assertion Event, "State Deasserted"

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.