Applies to

  • FAS2650
  • DS212C Disk shelf
  • ONTAP upgrade

Issue

  • Controller not responding during upgrade
  • Boot process hangs with message Entering FM state:5 because mbFound:0 local inheadswap:0
  • Eventually, controller reboots due to no root volume found

WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)
Uptime: 6m10s
System rebooting...

 

  • No disks can be seen in maintenance mode

*> disk show -v
Local System ID: 123456789

disk show: No disks attached to system.

  • Shelves and disks information is missing from SAS adapters in maintenance mode

        slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
                Firmware rev:       03.08.09.00
                Base WWN:           5:00a098:00aec1a:30
                Temperature:        Not Available
                Phy State:          [0] Enabled, 12.0 Gb/s
                                    [1] Enabled, 12.0 Gb/s
                                    [2] Enabled, 12.0 Gb/s
                                    [3] Enabled, 12.0 Gb/s
                Mini-SAS HD Vendor:        Amphenol        
                Mini-SAS HD Part Number:   X66032A+A0      
                Mini-SAS HD Type:          Passive Copper (unequalized) 2m ID:01
                Mini-SAS HD Serial Number: APF16340162481
        slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
                Firmware rev:       03.08.09.00
                Base WWN:           5:00a098:00aec1a:34
                Temperature:        Not Available
                Phy State:          [4] Enabled, 12.0 Gb/s
                                    [5] Enabled, 12.0 Gb/s
                                    [6] Enabled, 12.0 Gb/s
                                    [7] Enabled, 12.0 Gb/s

  • sasadmin expander_map shows correct cabling for adapter 0b but corrupted information for adapter 0a (e.g. missing shelf serial number)​​​​​​​​​​​​​​   

Expanders on channel 0a: 
Level    0: WWN 500a098007cb4815, ID  0, Serial Number '                ', Product '', Rev '', Slot A
Level    1: WWN 500a098007cb47b5, ID  0, Serial Number '                ', Product '', Rev '', Slot A

Expanders on channel 0b: 
Level    1: WWN 500a09800aec1a3f, ID  0, Serial Number ' SHFHU1736000204', Product 'DS22412IOM12E   ', Rev '0230', Slot A
Level    2: WWN 500a098007cb4811, ID  2, Serial Number ' SHFHU1739000214', Product 'DS22412IOM12A   ', Rev '0281', Slot A
Level    3: WWN 500a098007cb47a5, ID  1, Serial Number ' SHFHU1739000215', Product 'DS22412IOM12A   ', Rev '0281', Slot A
​​​​​​​

  • Removing the SAS cable from adapter 0a allows the system to see disks again and boot
  • Reseating/replacing IOM module and SAS cable do not solve the issue

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.