Applies to

  • FAS2720
  • ONTAP 9

Issue

  • Node B experiences a PANIC REBOOT and transitions to the Loader prompt due to inaccessible boot media.

PANIC: thread (swi4: clock (0)) on cpu 11 hung for 4001 milliseconds in process swi4: clock (0) on release 9.7P12 (C) on Fri Mar 7 11:05:17 JST 2025

  • During the boot media replacement on Node B, Node A detects a shelf fault and node B is PC INSUFFICIENT POWER critical status.

EMS log:

<LR d="11Mar2025 12:31:16" n="node-01" ・・・・

<ses_status_procCplxError_1

        prodChannel="DS212-12 (S/N SHXXXXXXXXXXX19) shelf 0 on channel 0b"

        typeText="Processor Complex"

        electrNumber="2"

        errorMsg="PCM on partner not installed"

        errorText=""

        locationText="This module is on the unknown location"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01" ・・・・

<monitor_shelf_fault_1

        channel="0b"/>

</LR>

<LR d="11Mar2025 12:40:34" n="node-01" ・・・・

<callhome_shlf_fault_1

        subject="SHELF_FAULT"/>

STORAGE-FAULT:

Enclosure Status: critical

Channel: 0b

Shelf: 0

Shelf Type: DS212-12

Product Serial Number: SHXXXXXXXXXXX19

Module Type: IOM12E

:

Vendor Unique Element 88-IOM12E: (PCM)

Element Status         Status Bytes  Status Descriptions

  1: OK                01,01,00,00  

  2: CRITICAL          02,01,00,01   PC INSUFFICIENT POWER

 

  • Sensor 2 has an error on the Processor Complex attached element.

ENVIRONMENT:

Environment for channel 0a
    Number of shelves monitored: 1    enabled: yes
    Environmental failure on shelves on this channel? yes

    Channel: 0a
    Shelf: 0
    SES device path: local access: 0b.00.99
    Module type: IOM12E; monitoring is active  
    Shelf status: critical condition
    SES Configuration, shelf 0:

    Processor Complex attached element list: 1, 2 with error: 2
    SAS Expander Module installed element list: 1, 2; with error: none
    SAS Expander master module: 1

  • Both nodes are in a multipath SAS connection state, and the IOM12E in critical status on Node B appears to be functioning normally.
  • Replacing Node B does not resolve the issue.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.