Node panics due to Flash Cache failure
Applies to
- ONTAP 9
- Flash Cache
Issue
- EMS log raise the following Flash Cache NVMe offline alert :
HA Group Notification (Flash Cache NVMe Offline) ALERT
- SYSCONFIG -Ashow Flash Cache become- failedstatus.
    slot 1: Flash Cache NVMe
        Serial Number:      ZEP0081C
        Part Number:        119-00329
        Hardware Revision:  A0
        Firmware Version:   NA03
        Model Name:         X3311A
        Capacity:           1024 GB
        State:              failed
- Node panics with the following message and a takeover/giveback is performed automatically after Flash Cache offline:
Panic String: Freeing freed block: pvbn 0 vvbn 306417665 in volumename@vserver:9b465b44-5102-11e9-9bb1-00a098fcXXXX. WAFL inconsistent.Contact NetApp technical support. in SK process wafl_exempt01 on release 9.5(C)