Skip to main content
NetApp Knowledge Base

Node down due to ses.status.temperatureWarning

Views:
25
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

Applies to

  • FAS2750

Issue

  • Node is down due to ses.status.temperatureWarning.
EMS-LOG-FILE.GZ
[?]  Tue Apr 22 18:48:46 JST [NODE-02: dsa_worker2: ses.status.temperatureWarning:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 0 on channel 0a temperature warning for Temperature sensor 14: not operating. Current temperature: 45 C (113 F). This module is on the rear of the shelf at the top right, on shelf module B.
[?]  Tue Apr 22 18:48:46 JST [NODE-02: dsa_worker2: ses.status.temperatureWarning:alert]: DS224-12 (S/N XXXXXXXXXXXXXXX) shelf 0 on channel 0a temperature warning for Temperature sensor 15: not operating. Current temperature: 31 C (87 F). This module is on the rear of the shelf at the top right, on shelf module B.
[?]  Tue Apr 22 18:52:43 JST [NODE-02: statd: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Multiple fans failed)
[?]  Tue Apr 22 18:52:43 JST [NODE-02: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Status of fans is unknown for 90 seconds. Shutting down now.
  • Sensors show Unavailable.
ENVIRONMENT
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: none
Shelf temperatures by element:
[1] 25 C (77 F) (ambient)  Normal temperature range
[2] 26 C (78 F)  Normal temperature range
[3] 26 C (78 F)  Normal temperature range
[4] 25 C (77 F)  Normal temperature range
[5] 25 C (77 F)  Normal temperature range
[6] 26 C (78 F)  Normal temperature range
[7] 26 C (78 F)  Normal temperature range
[8] 25 C (77 F)  Normal temperature range
[9] 26 C (78 F)  Normal temperature range
[10] 32 C (89 F)  Normal temperature range
[11] 41 C (105 F)  Normal temperature range
[12] 30 C (86 F)  Normal temperature range
[13] 30 C (86 F)  Normal temperature range
[14] Unavailable
[15] Unavailable
  • The issue can not be resolved by upgrading BMC to the latest version.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.