Node down and partner node triggers PSU critical error
Applies to
- AFF-A300
- FAS8200
- FAS2720
- ONTAP 9
Issue
- Node panic and SP can't be accessed.
- Partner node triggers the following PSU errors.
HA Group Notification (Health Monitor process cphm: CriticalFruMultiFaultAlert[PSQ0A2184600020]) ALERT
HA Group Notification (CHASSIS POWER SUPPLY DEGRADED: PS 1) ERROR
HA Group Notification (CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU1, PSU2.) ERROR
- On partner node PSU1 and PSU2 shows
BAD
status fromsp-latest-ipmi
sp-latest-ipmi:
/usr/local/bin/environ -show_all
================================
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
PSU2 Bad TRUE
PSU1 Bad TRUE
PSU2 need replacement NO
PSU1need replacement NO
PSU2 BAD
PSU1 BAD