Node down after BMC upgrade to 11.9, IPMI failure

Views:
930
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • FAS2720, FAS2750
  • AFF A220
  • BIOS on 11.8 or earlier
  • BMC firmware upgrade to 11.9 or later

Issue

  • After a BMC firmware upgrade to BMC 11.9 or later while on BIOS version 11.8 or earlier, one or both nodes reboot the BMC to its backup firmware and fail to boot.
  • The following errors are seen:

LOADER-B> boot_ontap

Device Drivers ...
Waiting for SP ...
SP failure. Resetting SP from primary FW. This can take a few minutes
Waiting for SP ...
SP failure. Resetting SP from backup FW. This can take a few minutes
Waiting for SP ...
Failed to recover SP
IPMI:Get controller FRU inventory:failed.   <<<<<<
Configuring Devices ...
IPMI PCI Slot Control failed.     <<<<<<
...
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT <<<<<<
LOADER-B>

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.