NoPathToNSMB_Alert after adding shelves to an existing config
- Views:
- 912
- Visibility:
- Public
- Votes:
- 1
- Category:
- disk-shelves
- Specialty:
- HW
- Last Updated:
- 8/10/2023, 7:32:27 PM
Applies to
- AFF A900, AFF A800, AFF A700, AFF A400, AFF A320
- New NS224 shelves added and working properly, following best practices for cabling
- Storage configuration change from directly-attached storage to switch-attached storage
- Cisco Nexus 3232C or 9336C-FX2 switch
Issue
- Health alert for both
NSMA
andNSMB
modules
Monitor node-connect
Alert ID NoPathToNSMA_Alert
Alerting Resource 01234567890123456789
Subsystem SAS-connect
Indication Time Sun May 08 21:34:51 2022
Perceived Severity Major
AutoSupport Triggered true
Probable Cause Cable_tamper
Corrective Actions 1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
2. Connect controller amsnapc01n01 to module A and module B of shelf 1.2.
- The alerts are raised and cleared periodically:
::> event log show -event hm.alert*
Time Node Severity Event
------------------- -------- -------- ---------------------------
4/22/2022 16:12:01 node_name-1 NOTICE hm.alert.cleared: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
4/22/2022 15:42:00 node_name-2 ALERT hm.alert.raised: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
- Repeated EMS messages:
...
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
...
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
- No storage switches listed in
system switch ethernet show
output.