Skip to main content
NetApp Knowledge Base

NoPathToNSMB_Alert after adding shelves to an existing config

Views:
738
Visibility:
Public
Votes:
1
Category:
disk-shelves
Specialty:
HW
Last Updated:

Applies to

  • AFF A900, AFF A800, AFF A700, AFF A400, AFF A320
  • New NS224 shelves added and working properly, following best practices for cabling 
  • Storage configuration change from directly-attached storage to switch-attached storage
  • Cisco Nexus 3232C or 9336C-FX2 switch

Issue

  • Health alert for both NSMA and NSMB modules

Monitor                 node-connect
Alert ID                NoPathToNSMA_Alert
Alerting Resource       01234567890123456789
Subsystem               SAS-connect
Indication Time         Sun May 08 21:34:51 2022
Perceived Severity      Major
AutoSupport Triggered   true
Probable Cause          Cable_tamper
Corrective Actions   1. Consult the guide applicable to your NVMe storage shelf to review cabling rules for your system.
                     2. Connect controller amsnapc01n01 to module A and module B of shelf 1.2.

  • The alerts are raised and cleared periodically: 

::> event log show -event hm.alert*
Time                Node      Severity   Event
------------------- --------  --------   ---------------------------
4/22/2022 16:12:01  node_name-1   NOTICE     hm.alert.cleared: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
4/22/2022 15:42:00  node_name-2   ALERT      hm.alert.raised: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • Repeated EMS messages:

...
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-1: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

...
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect
[node_name-2: nchmd: hm.alert.cleared:notice]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 cleared by monitor node-connect
[node_name-2: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMB_Alert , Alerting Resource = 01234567890123456789 raised by monitor node-connect

  • No storage switches listed in system switch ethernet show output.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.