Newly upgraded cluster switch shows as the old switch model
Applies to
- ONTAP 9
- CN1610
- BES-53248
Issue
- Switches were upgraded from CN1610 to BES-53248 and the original CN1610 hostname was retained
- Newly added switches showing up as old switch model despite new device being connected
cluster-1::>system cluster-switch show
sw-1 cluster-network 172.30.32.13 CN1610
Serial Number: Unknown
Is Monitored: true
Reason: None
Software Version: 3.8.0.2
Version Source: CDP/ISDP
cluster-1::>network device-discovery show -node node-1 -protocol cdp
Node/ Local Discovered
Protocol Port Device (LLDP: ChassisID) Interface Platform
----------------- ------------------------- ---------------- ----------------
node-1/cdp
e0a sw-1 0/1 BES-53248
e0b sw-2 0/1 BES-53248