NS224 Shelf sensor 9 reports over temperature
Applies to
- NS224
Issue
- Temp sensor 9 reports over temperature and clears
[?] Sun Mar 01 15:22:43 +0100 [Node01: dsa_worker0: ses.status.temperatureWarning:alert]: NS224NSM100B (S/N 952506001287) shelf 22 on channel 0x temperature warning for Temperature sensor 9: non-critical status; overtemperature warning. Current temperature: 56 C (132 F). This element is on the unknown location.
[?] Sun Mar 01 21:55:10 +0100 [Node01: dsa_worker0: ses.status.temperatureInfo:info]: NS224NSM100B (S/N 952506001287) shelf 22 on channel 0x temperature information for Temperature sensor 9: normal status.
Temperature Sensors:Element Status Status Bytes Status Descriptions 9: NONCRITICAL 03,00,4C,04 OT WARNING <-----
Shelf temperatures by element: [9] 56 C (132 F) Overtemperature warning! <---- NSM A - Ethernet inlet
All other temp sensors are in normal range- Shelf firmware is up to date with version 0404
- Soft reboot / re-seating the module does not clear the alert