NS224 DISK REDUNDANCY FAILED ERROR after disk replacement with no missing drives
Applies to
- NS224 shelf running fw. 2.10
- Disk replacement after failure
Issue
- Disk failed and replaced
- After disk replacement, AutoSupport send messages with:
[...: dsa_disc: callhome.dsk.redun.fault:debug]: Call home for DISK REDUNDANCY FAILED- NSM100 module issue reported but cleared
[node_name-01: mgwd: callhome.hm.alert.major:debug]: Call home for Health Monitor process schm: NoPathFromSwitchToNSM_Alert[1.1:A].Alert ID NoPathFromSwitchToNSM_AlertDescription Storage shelf 1.1 module A is not connected to storage switches.Corrective Actions Connect shelf 1.1 module A to two storage switches, following the guide applicable to your shelf.Possible Effect Access to shelf 1.1 can be lost with a single shelf module failure.[node_name-01: schmd: hm.alert.cleared:debug]: Alert Id = NoPathFromSwitchToNSM_Alert , Alerting Resource = 1.2:A cleared by monitor system-connect- System storage transition from Quad-Path to Mixed-Path HA
[node_name-01: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.[node_name-02: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
- Replaced disk is not reporting the paths/connections through the other NSM100 module.
- Discovered paths
node_name-02:e4b.01.1.5node_name-02:e4a.01.0.5node_name-01:e4b.01.1.5node_name-01:e4a.01.0.5-
- Missing paths:
node_name-01:e4a.01.2.5node_name-01:e4b.01.3.5node_name-02:e4b.01.3.5node_name-02:e4a.01.2.5- No erros found in any shelf component, including disks.
- The issue remains after the disk replacement / re-seat
- The issue remains after the NSM100 A module re-seat
- The issue remains after both NSM100 modules
'soft reboot'