Multiple dive failure of model X316_HARIH06TA07
Applies to
- Disk drives of model X316_HARIH06TA07
- FAS/AFF
Issue
- Multiple drives fail with model X316_HARIH06TA07 with the
disk.write.failure
orioMedium
errors. - The system might display the following EMS errors due to drive failure:
[Node-01:disk_server_1: disk.ioMediumError:notice]: Medium error on disk 2a.66.1: op 0x2a:5a438a00:0200 sector 1514375890 SCSI:medium error - If the disk is in a RAID group, the subsystem will attempt to reconstruct unreadable data (3 3 0 eb)
[Node-01: disk_server_0: disk.write.failure:debug]: params: {'diskName': '0b.25.6', 'fa2': '0x0', 'serialno': '1EHLZZJF', 'fa0': '0xf3', 'fa1': '0x11', 'state': '0x5', 'fa3': '0x2d', 'disk_information': 'Disk 0b.25.6 Shelf 25 Bay 6 [NETAPP X316_HARIH06TA07 NA00] S/N [1XXXXXXXF] UID [5000CCA2:325AE9FC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]'}