Skip to main content
NetApp Knowledge Base

Module firmware upgrade stuck on NS224 shelf

Views:
1,577
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
HW
Last Updated:

Applies to

  • NS224 shelf
  • NSM100 Firmware upgrade

Issue

  • During a firmware upgrade on a NSM100 module, the automatic upgrade process never completes.
  • When trying to perform the upgrade manually, a message similar to the one below may be observed:

Cluster::*> storage shelf firmware update -shelf 10.1

Error: Shelf firmware update request failed on node "node1".
Reason: Shelf firmware update already in progress.
 
  • Sometimes the following errors will be seen in the EMS when the firmware update gets stuck
[Node-1: dsa_worker4: ses.status.temperatureWarning:alert]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x temperature warning for Temperature sensor 12: not installed or failed. Current temperature: 23 C (73 F). This element is on the unknown location.
[Node-1: dsa_worker4: ses.status.electronicsWarn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker4: ses.status.ModuleWarn:alert]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x PCI switch warning for PCI Switch 2: communication error. This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker4: ses.status.battery.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x battery failure error for Coin Battery 2: not installed or hardware failure. This element is on the rear of the shelf, in bottom module (B).
[Node-1: dsa_worker4: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x Ethernet connector warning for port e0a: cannot communicate with connector.  This element is on the rear of the shelf at the bottom, on le B.
[Node-1: dsa_worker4: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x Ethernet connector warning for port e0b: cannot communicate with connector.  This element is on the rear of the shelf at the bottom, on module B.
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 5: not installed or failed. This element is on the DIMM slot 1 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 6: not installed or failed. This element is on the DIMM slot 2 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 7: not installed or failed. This element is on the DIMM slot 3 in the bottom shelf module (B).
[Node-1: dsa_worker2: ses.status.dimm.error:error]: NS224NSM100 (S/N SHFHU2119000112) shelf 11 on channel 0x DIMM failure for Dimm Element 8: not installed or failed. This element is on the DIMM slot 4 in the bottom shelf module (B).

 
  • Autosupport message generated 'DISK REDUNDANCY FAILED'

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.