Inlet ODP Temp sensor high thresholds change unexpectedly
Applies to
- AFF A1K, AFF A90, AFF A70, AFF C80
- AFX 1K, AFX 2K
- ASA A1K, ASA A90, ASA A70
- FAS90, FAS70
Issue
- It may be observed that under certain conditions, the "Warning High" and "Critical High" threholds for the Inlet ODP Temp sensors change from 42C/47C to 35C/40C:
Sensor Name State Current Critical Warning Warning Critical
Reading Low Low High High
-------------------------------------------------------------------------------------------------
Inlet ODP Temp1 normal 33 C 0 C 3 C 42 C 47 C
Inlet ODP Temp2 normal 34 C 0 C 3 C 42 C 47 C
Inlet ODP Temp1 warnhigh 39 C 0 C 3 C 35 C 40 C
Inlet ODP Temp2 warnhigh 39 C 0 C 3 C 35 C 40 C
- These ambient temperature sensors are called "Bezel Temp 1 and Bezel Temp 2" on 2U single-controller systems, such as: AFF A1K, ASA A1K, FAS90, FAS70.