Skip to main content
NetApp Knowledge Base

InBand ACP critical failure in both IOM12 modules of external shelf

Views:
521
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:
3/12/2025, 8:55:25 PM

Applies to

  • ACP processor
  • IOM12 shelves

Issue

  • Critical external shelf alert example:
ALERT         monitor.shelf.fault: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
 
::> storage shelf show
Module Operational
Shelf Name        Shelf ID Serial Number   Model       Type   Status
----------------- -------- --------------- ----------- ------ -----------
1.1               1        SHFHU1234567890 DS224-12    IOM12  Normal
2.11              11       SHFHU1234567891 DS224-12    IOM12  Normal
2.12              12       SHFHU1234567892 DS224-12    IOM12  Critical
3 entries were displayed.
  • ACP error example: 
::> storage shelf show -errors
Shelf Name: 2.12
Shelf UID: 50:0a:0b:0c:0d:0a:0b:0c
Serial Number: SHFHU1234567892
Error Type         Description
------------------ ---------------------------
ACPP               -
ACPP               -
  • storage shelf fault output example:
Enclosure Status: critical
Channel: 0b
Shelf: 12
Shelf Type: DS224-12
Product Serial Number: SHFHU1234567893
Module Type: IOM12
Vendor Unique Element 85-IOM12: (ACP)
Element Status                     Status Bytes  Status Descriptions
1 [IOM12 A]    : CRITICAL          02,18,00,40   NO ACPP, INBACP, FAIL
2 [IOM12 B]    : CRITICAL          02,18,00,40   NO ACPP, INBACP, FAIL
  • The issue remains after the shelf firmware updated:
::> storage shelf show -fields module-fw-revision
shelf module-fw-revision
----- ------------------
1.1   0310,0310
2.11  0310,0310
2.12  0310,0310
3 entries were displayed.
  • The issue remains after disabling/enabling the ACP subsystem

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.