IFGRP down with flapping member ports
- Views:
- 5,801
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems
- Specialty:
- hw
- Last Updated:
- 8/7/2024, 9:36:37 AM
Applies to
- FAS8200
- ONTAP 9.3P5
- 2 node Metrocluster
Issue
- IFGRP used in LACP configuration goes down
- IFGRP member ports e0a/e0b are connected to different switches
- Ports intermittently transition from up to down state, then recover
- Messages observed on the system:
7/7/2021 22:46:51 node-01 ALERT vifmgr.lifdown.noports: LIF node_icl1 (on virtual server 4294967295), IP address XXX.XXX.XXX.XXX, currently cannot be hosted on node node-01, port a0a-2, or any of its failover targets, and is being marked as down.
7/7/2021 22:46:38 node-01 ALERT vifmgr.lifdown.noports: LIF intercluster_n1 (on virtual server 4294967295), IP address XXX.XXX.XXX.XXX, currently cannot be hosted on node node-01, port a0a-2, or any of its failover targets, and is being marked as down.
7/7/2021 22:46:35 node-01 ERROR net.ifgrp.lacp.link.inactive: ifgrp a0a, port e0b has transitioned to an inactive state. The interface group is in a degraded state.
7/7/2021 22:46:35 node-01 ERROR net.ifgrp.lacp.link.inactive: ifgrp a0a, port e0a has transitioned to an inactive state. The interface group is in a degraded state.