Getting error while running"sensor show" API call
- Views:
- 24
- Visibility:
- Public
- Votes:
- 0
- Category:
- disk-shelves
- Specialty:
- hw
- Last Updated:
- 9/16/2024, 10:15:35 AM
Applies to
Issue
- API calls are showing the following errors:
Shelf 1.2(SHJGD1918000060): Fru 2 status error.
Shelf 1.2(SHJGD1918000060): Fru 3 status error.
Shelf 1.2(SHJGD1918000060): Sensor 5 status error.
Shelf 1.2(SHJGD1918000060): Sensor 6 status error.
Shelf 1.2(SHJGD1918000060): Sensor 7 status error.
Shelf 1.2(SHJGD1918000060): Sensor 8 status error.
Shelf 1.2(SHJGD1918000060): Sensor 3 status error.
Shelf 1.2(SHJGD1918000060): Sensor 4 status error.
Shelf 1.2(SHJGD1918000060): Sensor 5 status error.
Shelf 1.2(SHJGD1918000060): Sensor 6 status error.
Shelf 1.2(SHJGD1918000060): Fan 3 status error. Located at rear of the shelf on the upper right power supply.
Shelf 1.2(SHJGD1918000060): Fan 4 status error. Located at rear of the shelf on the upper right power supply.
Shelf 1.2(SHJGD1918000060): Fan 5 status error. Located at rear of the shelf on the lower left power supply.
Shelf 1.2(SHJGD1918000060): Fan 6 status error. Located at rear of the shelf on the lower left power supply.
Shelf 1.2(SHJGD1918000060): Sensor 3 status error. . Shelf 1.2(SHJGD1918000060): Sensor 4 status error. .
Shelf 1.2(SHJGD1918000060): Sensor 5 status error. . Shelf 1.2(SHJGD1918000060): Sensor 6 status error.
- No further errors seen in the cluster.
- Storage show fault -v shows that the these modules are not installed:
Enclosure Status: normal
Shelf Type: DS4246
Module Type: IOM6
Power Supplies:
Element Status Status Bytes Status Descriptions
1: OK 01,00,00,20 RQSTED ON
2: NOT INSTALLED 05,00,00,20
3: NOT INSTALLED 05,00,00,20
4: OK 01,00,00,20 RQSTED ON
Fans:
Element Status Status Bytes Status Descriptions
1: OK 01,01,36,21
2: OK 01,01,36,21
3: NOT INSTALLED 05,00,00,20
4: NOT INSTALLED 05,00,00,20
5: NOT INSTALLED 05,00,00,20
6: NOT INSTALLED 05,00,00,20
7: OK 01,01,36,21
8: OK 01,01,31,21
Temperature Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,2A,00
2: OK 01,00,2F,00
3: OK 01,00,30,00
4: OK 01,00,44,00
5: NOT INSTALLED 05,00,00,00
6: NOT INSTALLED 05,00,00,00
7: NOT INSTALLED 05,00,00,00
8: NOT INSTALLED 05,00,00,00
9: OK 01,00,31,00
10: OK 01,00,45,00
11: OK 01,00,31,00
12: OK 01,00,31,00
Voltage Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,01,FF
2: OK 01,00,04,C2
3: NOT INSTALLED 05,00,00,00
4: NOT INSTALLED 05,00,00,00
5: NOT INSTALLED 05,00,00,00
6: NOT INSTALLED 05,00,00,00
7: OK 01,00,01,FF
8: OK 01,00,04,BE
Current Sensors:
Element Status Status Bytes Status Descriptions
1: OK 01,00,03,4F
2: OK 01,00,01,E0
3: NOT INSTALLED 05,00,00,00
4: NOT INSTALLED 05,00,00,00
5: NOT INSTALLED 05,00,00,00
6: NOT INSTALLED 05,00,00,00
7: OK 01,00,03,15
8: OK 01,00,01,B1