Applies to

DS4246

Issue

  • API calls are showing the following errors:

Shelf 1.2(SHJGD1918000060): Fru 2 status error.
Shelf 1.2(SHJGD1918000060): Fru 3 status error.
Shelf 1.2(SHJGD1918000060): Sensor 5 status error.
Shelf 1.2(SHJGD1918000060): Sensor 6 status error.
Shelf 1.2(SHJGD1918000060): Sensor 7 status error.
Shelf 1.2(SHJGD1918000060): Sensor 8 status error.
Shelf 1.2(SHJGD1918000060): Sensor 3 status error.
Shelf 1.2(SHJGD1918000060): Sensor 4 status error.
Shelf 1.2(SHJGD1918000060): Sensor 5 status error.
Shelf 1.2(SHJGD1918000060): Sensor 6 status error.
Shelf 1.2(SHJGD1918000060): Fan 3 status error. Located at rear of the shelf on the upper right power supply.
Shelf 1.2(SHJGD1918000060): Fan 4 status error. Located at rear of the shelf on the upper right power supply.
Shelf 1.2(SHJGD1918000060): Fan 5 status error. Located at rear of the shelf on the lower left power supply.
Shelf 1.2(SHJGD1918000060): Fan 6 status error. Located at rear of the shelf on the lower left power supply.
Shelf 1.2(SHJGD1918000060): Sensor 3 status error. . Shelf 1.2(SHJGD1918000060): Sensor 4 status error. .
Shelf 1.2(SHJGD1918000060): Sensor 5 status error. . Shelf 1.2(SHJGD1918000060): Sensor 6 status error.    

  • No further errors seen in the cluster.
  • Storage show fault -v shows that the these modules are not installed:

Enclosure Status: normal
Shelf Type: DS4246
Module Type: IOM6

Power Supplies:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,00,20   RQSTED ON
  2: NOT INSTALLED     05,00,00,20
  3: NOT INSTALLED     05,00,00,20
  4: OK                01,00,00,20   RQSTED ON

Fans:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,01,36,21
  2: OK                01,01,36,21
  3: NOT INSTALLED     05,00,00,20
  4: NOT INSTALLED     05,00,00,20
  5: NOT INSTALLED     05,00,00,20
  6: NOT INSTALLED     05,00,00,20
  7: OK                01,01,36,21
  8: OK                01,01,31,21

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,2A,00
  2: OK                01,00,2F,00
  3: OK                01,00,30,00
  4: OK                01,00,44,00
  5: NOT INSTALLED     05,00,00,00
  6: NOT INSTALLED     05,00,00,00
  7: NOT INSTALLED     05,00,00,00
  8: NOT INSTALLED     05,00,00,00
  9: OK                01,00,31,00
 10: OK                01,00,45,00
 11: OK                01,00,31,00
 12: OK                01,00,31,00

Voltage Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,01,FF
  2: OK                01,00,04,C2
  3: NOT INSTALLED     05,00,00,00
  4: NOT INSTALLED     05,00,00,00
  5: NOT INSTALLED     05,00,00,00
  6: NOT INSTALLED     05,00,00,00
  7: OK                01,00,01,FF
  8: OK                01,00,04,BE

Current Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,03,4F
  2: OK                01,00,01,E0
  3: NOT INSTALLED     05,00,00,00
  4: NOT INSTALLED     05,00,00,00
  5: NOT INSTALLED     05,00,00,00
  6: NOT INSTALLED     05,00,00,00
  7: OK                01,00,03,15
  8: OK                01,00,01,B1     
                                                                                                                                                                                                                                                                                                                                  

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.