Fault LED turns on and off repeatedly
Applies to
- FAS9000
- ONTAP 9.x
Issue
P3V3_BATT error event can be found in the following command output.
Example:
cluster::> system controller service-event show
Node ID Event Location Event Description
---------------- --- ---------------------------------- ----------------------
node 1 Coin-cell battery on Controller B ipmi P3V_BATT lower non-critical
SP node> system service-event show
ID FRU Description Fault Reason
--- ------------------------ ------------------
1 Coin-cell battery on Controller B ipmi P3V_BATT lower non-critical
Fault Lights On:
/chassis-1
Controller B
Coin-cell battery on Controller B