FC port goes offline due to multiple flaps in Fabric MetroCluster system
Applies to
- ONTAP 9
- Fabric-Attached MetroCluster
Issue
- The FC host adapter starts flapping on a node and is brought offline:
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_asyncd_0: fci.adapter.link.online:info]: Fibre Channel adapter 2b link online.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: slifc_timeout_0: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2b after 30 seconds. Taking the adapter offline.
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2b.
[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (2b)
- The port status shows offline from the sysconfig -a output:
::> system node run -node <node> sysconfig -a
slot 2: FC Host Adapter 2b (Emulex XE201 rev. 48, <OFFLINE (hard)>)
          Board name:        111-02451
          Serial Number:     FCXXXXX828
          Firmware rev:      12.0.378.1
          Host Port Id:      N/A
          FC Node Name:      2:000:00XXXX:4fXXXX
          FC Port Name:      1:000:00XXXX:4fXXXX
          SFP Vendor:        FINISAR CORP.
          SFP Part Number:   FTLF8529P4BCVAN1
          SFP Serial Number: P3AB3S2
          SFP Capabilities:  4, 8 or 16 Gbit
          Link Data Rate:    N/A
- A lot of link failures can be seen on the switch port connected to the FC port on the node:
porterrshow:
          frames   enc   crc  crc    too  too  bad  enc  disc  link  loss  loss  frjt  fbsy  c3timeout   pcs   uncor
       tx     rx   in    err  g_eof  shrt long eof  out   c3   fail  sync   sig              tx    rx    err    err
  0:   2.3g   3.4g  0    0      0      0    0   0    0    500    9     0     9     0    0     0     0     0      0
  1:   2.6g   2.1g  0    0      0      0    0   0    0     9     38    0     4     0    0     0     0     0      0