  • FAS2820
  • Fixed BIOS version for bug 1582753

Issue

  • FAS 2820 node fails to boot past the following errors:

Personality check: BMC check failed
Personality check: Partner is not compatible

  • Sensors on chassis for affected node reports failed:

PSU2 Bad                 invalid            --
PSU1 Bad                 invalid            --
PSU2                     invalid            --
PSU1                     invalid            --
PSU2 ON                  invalid            --
PSU1 ON                  invalid            --
PSU2 INFO                               FAILED
PSU1 INFO                               FAILED
PSU1 FRU                 invalid            --
PSU2 FRU                 invalid            --
Partner Status           failed             –
PSU1 Present                            PRESENT
PSU1 5V                  init_failed       – mV       –          --          --          --       
PSU1 12V                 init_failed       – mV       –          --          --          --       
PSU1 5V Curr             init_failed       – mA       –          --          --          --       
PSU1 12V Curr            init_failed       – mA       –          --          --          --       
PSU1 Fan 1               init_failed       – RPM      --          --          --          --       
PSU1 Fan 2               init_failed       – RPM      --          --          --          --       
PSU1 Inlet Temp          init_failed       – C        --          --          --          --       
PSU1 Hotspot Temp        init_failed       – C        --          --          --          --       
PSU2 Present                            PRESENT
PSU2 5V                  init_failed       – mV       –          --          --          --       
PSU2 12V                 init_failed       – mV       –          --          --          --       
PSU2 5V Curr             init_failed       – mA       –          --          --          --       
PSU2 12V Curr            init_failed       – mA       –          --          --          --       
PSU2 Fan 1               init_failed       – RPM      --          --          --          --       
PSU2 Fan 2               init_failed       – RPM      --          --          --          --       
PSU2 Inlet Temp          init_failed       – C        --          --          --          --       
PSU2 Hotspot Temp        init_failed       – C        --          --          --          --       
PSU_FAN                  failed             –
Module B Expander Temp   init_failed       – C        --          --          --          --       
Module A Expander Temp   init_failed       – C        --          --          --          --       
Midplane 4 Temp          init_failed       – C        --          --          --          --       
Midplane 3 Temp          init_failed       – C        --          --          --          --       
Midplane 2 Temp          init_failed       – C        --          --          --          --       
Midplane 1 Temp          init_failed       – C        --          --          --          --       
Ambient Temp             init_failed       – C        --          --          --          --       
disk fault status        failed             –
Supported Shelf          failed             –
Internal Shelf           failed   

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.