EMS reports "ses.status.temperatureWarning:alert"
Applies to
Issue
- EMS reports "ses.status.temperatureWarning:alert"
Example:
[node01: dsa_worker3: ses.status.temperatureWarning:alert]: DS2246 (S/N SHFFGXXXXXXXXXX) shelf 10 on channel 0a temperature warning for Temperature sensor 7: not installed or failed. Current temperature: 27 C (80 F). This module is on the rear of the shelf at the top left, on shelf module A.or[ses.status.temperatureWarning:alert]: DS212-12 (S/N ***) shelf 13 on channel 3d temperature warning for Temperature sensor 2: not installed or failed. Current temperature: 28 C (82 F). This module is on the inside of the shelf on the midplane.[ses.status.ModuleWarn:alert]: DS212-12 (S/N ***) shelf 13 on channel 3d SAS expander warning for SAS shelf electronics 1: communication error. This module is on the rear of the shelf at the top left, on shelf module A.[ses.status.ACPWarn:error]: DS212-12 (S/N*** ) shelf 13 on channel 3d ACP Processor warning for SAS shelf ACP processor 1: communication error. ; Alternate Control Path hardware failed This module is on the rear of the shelf at the top left, on shelf module A.
- Examining
environmentin ASUP:
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8; with error: none
Shelf temperatures by element:
[1] 22 C (71 F) (ambient) Normal temperature range
[2] 25 C (77 F) Normal temperature range
[3] 26 C (78 F) Normal temperature range
[4] 49 C (120 F) Normal temperature range
[5] 26 C (78 F) Normal temperature range
[6] 49 C (120 F) Normal temperature range
[7] Unavailable >>>>>>>>>> IOM A
[8] 28 C (82 F) Normal temperature range