Issue
- EMS log reports
scsi cmd checkCondition
errors on one disk and the errors recover automatically
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f1e7200:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f1e7200:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f840e00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f840e00:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:0000000170f82a00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="2" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:0000000170f82a00:00000200" dTime="96"
- Other log output examples
[node: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:bb0a0800:0400: Sense Data SCSI:no sense - (0x0 - 0x0 0x0 0x0)(32). ......
[node: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0d.01.7: request successful after retry #0/#12: cdb 0x88:00000002f243ddc0:00000008 (20148).
- Syslog event details
Ems Identifier | scsi.cmd.checkCondition |
Syslog Message | %s device %s: Check Condition: CDB %s: Sense Data %s - %s (0x%x - 0x%x 0x%x 0x%x)(%d). %s |
Severity | ERROR |
Description | This message occurs when a check condition is received from a device. A check condition is the mechanism whereby a target device reports an informational condition or error status to the requesting host. Either the condition that generated this event is an error that occurred during execution of the command and was not cleared by retrying the request or an informational condition reporting status of the present operation or media state. |
- Drive reports missing:
12:33:45 +0100 [node4: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1_SAS_euhstorp13/plex0/rg0/bsasswpj5-2:9.126L91 Shelf 0 Bay 10 [NETAPP X343_HCBFE1T8A10 NA06] S/N [08H5L03A] UID [5000CCA0:2C4283C4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.