Skip to main content
NetApp Knowledge Base

EMS log reports "scsi cmd checkCondition" error on disk

Views:
7,537
Visibility:
Public
Votes:
9
Category:
fas-systems
Specialty:
hw
Last Updated:
12/17/2024, 6:29:51 PM

Applies to

  • ONTAP 9
  • Drives

Issue

  • EMS log reports scsi cmd checkCondition errors on one disk and the errors recover automatically

[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f1e7200:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f1e7200:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:000000016f840e00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="1" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:000000016f840e00:00000200" dTime="118"
[node: Error] scsi_cmdblk_strthr_admin scsi cmd checkCondition: deviceType="Disk" deviceName="0b.00.10" cdb="0x88:0000000170f82a00:00000200" sSenseKey="SCSI:aborted command" sSenseCode="" iSenseKey="0xb" iASC="0x4b" iASCQ="0x3" iFRU="0x0" DTime="2" disk_information=""
[node: Debug] pmcsas_admin_0 scsi cmd retrySuccess: deviceType="Disk" deviceName="0b.00.10" retryCount="1" freeRetryCount="0" cdb="0x88:0000000170f82a00:00000200" dTime="96"

  • Other log output examples

[node: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:bb0a0800:0400: Sense Data SCSI:no sense - (0x0 - 0x0 0x0 0x0)(32). ...... 
[node: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0d.01.7: request successful after retry #0/#12: cdb 0x88:00000002f243ddc0:00000008 (20148).

  • Syslog event details
Ems Identifier scsi.cmd.checkCondition
Syslog Message %s device %s: Check Condition: CDB %s: Sense Data %s - %s (0x%x - 0x%x 0x%x 0x%x)(%d). %s
Severity ERROR
Description This message occurs when a check condition is received from a device. A check condition is the mechanism whereby a target device reports an informational condition or error status to the requesting host. Either the condition that generated this event is an error that occurred during execution of the command and was not cleared by retrying the request or an informational condition reporting status of the present operation or media state.

 

  • Drive reports missing:

12:33:45 +0100 [node4: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr1_SAS_euhstorp13/plex0/rg0/bsasswpj5-2:9.126L91 Shelf 0 Bay 10 [NETAPP   X343_HCBFE1T8A10 NA06] S/N [08H5L03A] UID [5000CCA0:2C4283C4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.