Many drives marked for prefail with badlabelversion during ONTAP upgrade
Applies to
- ONTAP upgrade
- FAS/AFF Systems
Issue
- Power cycle, unexpected reboot or panic of nodes with different ONTAP versions running
- Example: during an ANDU (Automatic Non-Disruptive Upgrade)
- Unplanned power cycle of a node
- Unexpected reboot of a node
- Panic of a node
- In ONTAP EMS logs, bad label messages are seen on disks:
raid.assim.disk.badlabelversion:alert]: Disk 0b.00.17P3 Shelf 0 Bay 17 [NETAPP X371_S1643960ATE NA55] S/N [xxxxxx] UID [xxxxxx] has RAID label with version (17), which is not within the currently supported range (5 - 16).
- Drives marked as prefailed after ONTAP upgrade completes: