Disk redundancy failed due to failed NSM
Applies to
- ONTAP 9
- NS224 shelf
Issue
- Disk redundancy failed due to failed NSM
[Node-01: start_asup_collector_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
[Node-01: start_asup_collector_thread: shelf.config.tospha:info]: System has transitioned to single path HA attached storage
- NoPathToNSMA_Alert
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = NoPathToNSMA_Alert , Alerting Resource = 530670491063066624 raised by monitor node-connect
- Ports connected to the failed NSM reports down in both Nodes
Node-01
slot 0: Dual 40G/100G Ethernet Controller CX5
e0c MAC Address: d0:39:ea:97:28:11 (auto-unknown-fd-down)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00573
QSFP Serial Number: APF22199567575
Node-02
e0d MAC Address: d0:39:ea:97:2a:dc (auto-unknown-fd-down)
QSFP Vendor: Amphenol
QSFP Part Number: 112-00573
QSFP Serial Number: APF22199567486
Device Type: CX5 PSID(NAP0000000005)
Firmware Version: 16.26.4012
- NSM still shows as failed even after performing reseat