Skip to main content
NetApp Knowledge Base

Disk fault LEDs toggle after unsupported shelf PSU event

Views:
3
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
HW
Last Updated:

Applies to

  • AFF A400
  • DS224-12
  • High availability (HA) pair configurations

Issue

  • EMS reports an unsupported status for shelf components, including the PSUs.

Example:

node-02(EMS)
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.fanInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d cooling fan information for Cooling element 1: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.fanInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d cooling fan information for Cooling element 2: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.fanInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d cooling fan information for Cooling element 3: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.fanInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d cooling fan information for Cooling element 4: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 1: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 2: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 3: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 4: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 5: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 6: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 7: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 8: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.temperatureInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d temperature information for Temperature sensor 9: unexpected (unsupported) status.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.electronicsWarn:error]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d environmental monitoring warning for SES electronics 1: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top left.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.electronicsWarn:error]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d environmental monitoring warning for SES electronics 2: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top right.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.enclInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d disk inclosure information for Enclosure 1: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.volInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d voltage information for Voltage sensor 1: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.volInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d voltage information for Voltage sensor 2: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.volInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d voltage information for Voltage sensor 3: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.volInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d voltage information for Voltage sensor 4: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.currentInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d current information for Current sensor 1: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.currentInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d current information for Current sensor 2: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.currentInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d current information for Current sensor 3: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.currentInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d current information for Current sensor 4: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d SAS connector information for SAS Connector 1: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d SAS connector information for SAS Connector 3: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d SAS connector information for SAS Connector 5: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.connectorInfo:info]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d SAS connector information for SAS Connector 7: unsupported configuration.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.ACPWarn:error]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d ACP Processor warning for SAS shelf ACP processor 1: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top left, on shelf module A.
Thu Jan 22 02:46:43 [node-02: dsa_worker0: ses.status.ACPWarn:error]: DS224-12 (S/N SHJSG2251xxxxxx) shelf 0 on channel 0d ACP Processor warning for SAS shelf ACP processor 2: component is from a different product family. ; unsupported configuration This module is on the rear of the shelf at the top right, on shelf module B.
Thu Jan 22 03:08:03 [node-02: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Thu Jan 22 03:38:03 [node-02: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Wed Jan 28 16:38:04 [node-02: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Wed Jan 28 17:08:04 [node-02: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.

node-01(EMS)

Wed Jan 28 15:54:16 [node-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Wed Jan 28 16:24:16 [node-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.
Wed Jan 28 16:54:16 [node-01: dsa_disc: ses.unsupported.shelf.psus:error]: Part number 114-00148+G1 not supported on Product ID DS224-12. 0a: 2 unsupported power supplies.

  • Multiple disk fault LEDs illuminate on the same shelf without disk failures
  • Disk fault LEDs turn off automatically after a period of time(~30s)
  • storage show fault -v shows disks in FAULT REQSTD state on one node while the HA partner reports normal status

EnclosureStatus:non-critical
Channel:0a
Shelf:0
ShelfType:DS224-12
ProductSerialNumber:SHJSG2251000188
ModuleType:IOM12B

DiskElements:
ElementStatusStatusBytesStatusDescriptions
0[Bay0]:OK01,00,00,00
1[Bay1]:OK01,01,00,00
2[Bay2]:OK01,02,00,00
3[Bay3]:OK01,03,00,00
4[Bay4]:OK01,04,00,00
5[Bay5]:OK01,05,00,00
6[Bay6]:OK01,06,00,00
7[Bay7]:OK01,07,00,00
8[Bay8]:OK01,08,00,00
9[Bay9]:OK01,09,00,00
10[Bay10]:OK01,0A,00,00
11[Bay11]:OK01,0B,00,00
12[Bay12]:OK01,0C,00,20 FAULTREQSTD
13[Bay13]:OK01,0D,00,20 FAULTREQSTD
14[Bay14]:OK01,0E,00,20 FAULTREQSTD
15[Bay15]:OK01,0F,00,20 FAULTREQSTD
16[Bay16]:OK01,10,00,20 FAULTREQSTD
17[Bay17]:OK01,11,00,20 FAULTREQSTD
18[Bay18]:OK01,12,00,20 FAULTREQSTD
19[Bay19]:OK01,13,00,20 FAULTREQSTD
20[Bay20]:OK01,14,00,20 FAULTREQSTD
21[Bay21]:OK01,15,00,20 FAULTREQSTD
22[Bay22]:OK01,16,00,20 FAULTREQSTD
23[Bay23]:OK01,17,00,20 FAULTREQSTD

  • No disk errors, no data access impact, and no service interruption observed

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.