Skip to main content
NetApp Knowledge Base

Node stuck in boot loop due to Device 20/0/0 (IO4) missing

Views:
445
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

Applies to

  • AFF-C80
  • AFF-A90
  • ASA-A90
  • NVRAM12 Module

Issue

  • Can't boot ONTAP.
  • Node enters a boot loop with the following error messages.

Initializing System Memory ...
Loading Device Drivers ...
Configuring Devices ...
Device 20/0/0 (IO4) missing
Device(s) in slot missing, attempting to recover it.
System is resetting.

Boot Loader version 8.4.4
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2025 NetApp, Inc. All Rights Reserved.
ACPI RSDP Found at 0x777fe014
BIOS POST Failure(s) detected: PCIe device missing error detected. Abort AUTOBOOT

  • The PCI-HIERARCHY.XML log confirms the NVRAM module in Slot 4.
--------------------------------------
Dv[000e](20,0,0) in slot 4: NETAPP NVRAM12 in slot 4 on Controller
-------------------------------------

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.