DegradedOnlineShelfPort_Alert reported
Applies to
- ONTAP 9
- External SAS disk shelves
- Directly attached SAS shelves
Issue
- DegradedOnlineShelfPort_Alert reported
::> system health alert show
Node: Node-01
Alert ID: DegradedOnlineShelfPort_Alert
Resource: Shelf 1.1
Severity: Major
Indication Time: Wed May 31 14:10:49 2023
Suppress: false
Acknowledge: false
Probable Cause: Shelf-to-shelf connection between disk shelves 1.1 3 port and 1.3 1 port have 2 inactive PHYs on IOM A.
Possible Effect: Inactive PHYs might cause degraded link performance.
Corrective Actions: 1. Consult the guide applicable to your IOM12 disk shelf to review cabling rules and complete the SAS cabling worksheet for your system.
2. Verify that disk shelf 1.1 has disabled PHYs by using the "storage shelf show -shelf 1.1 -port" command.
3. If the disk shelves have multiple paths to the node, reseat disk shelf 1.1 3 port cable on IOM A and disk shelf 1.3 1 port cable on IOM A.
4. Verify that the physical cable connection is secure and operational, and replace the cable, if necessary.
- Environment status shows high DWord counters
Shelf name: 0a.shelf13
Shelf id: 13
Channel: 0a
Module: A
Term switch: N/A
Shelf state: ONLINE
Module state: OK
Partial Path Link Invalid Running Loss Phy CRC Phy
Disk Port Timeout Rate DWord Disparity Dword Reset Error Change
Id State Value (ms) (Gb/s) Count Count Count Problem Count Count
--------------------------------------------------------------------------------------------
[HST0] OK 7 12.0 0 0 0 0 0 1
[HST1] OK 7 12.0 0 0 0 0 0 1
[HST2] OK 7 12.0 0 0 0 0 0 1
[HST3] OK 7 12.0 0 0 0 0 0 1
[HST4] EMPTY 7 NA 0 0 0 0 0 0
[HST5] EMPTY 7 NA 0 0 0 0 0 0
[HST6] EMPTY 7 NA 0 0 0 0 0 0
[HST7] EMPTY 7 NA 0 0 0 0 0 0
[HST8] DIS/INVWD 7 NA 45951 45920 0 0 0 4
[HST9] OK 7 12.0 0 0 0 0 0 3