DISK REDUNDANCY FAILED during replacing disk on DS460C
Applies to
- ONTAP 9
- DS460C
Issue
- Storage shelf log for replacing the disk:
Wed Feb 21 08:20:45 2024 ( 149+05:10:55.382); 03030052; S; ENC_MGT; drive_manager; 02; Clearing faults on removed drive: 17
Wed Feb 21 08:20:53 2024 ( 149+05:11:03.527); 0303006C; S; ENC_MGT; drive_manager; 04; Link up because of insertion drive: 17
Wed Feb 21 08:20:56 2024 ( 149+05:11:05.996); 0303006C; S; ENC_MGT; drive_manager; 04; Link up because of power-on drive: 17
- After replacing the disk, show
DISK REDUNDANCY FAILED
Wed Feb 21 16:21:14 +0800 [node01: svc_queue_thread: shelf.config.tomixedha:notice]: System has transitioned to a mixture of single, multi-path or quad-path storage configurations.
Wed Feb 21 16:21:14 +0800 [node01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
- The system returns to multi-path HA in short time:
Wed Feb 21 16:22:47 +0800 [node01: svc_queue_thread: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage