Skip to main content
NetApp Knowledge Base

DISK REDUNDANCY FAILED by incorrect cabling

Views:
827
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

Applies to

  • ONTAP 9
  • Shelf cabling

Issue

EMS reports HA Group Notification from Storage06-02 (DISK REDUNDANCY FAILED) ERROR.

[?] Sun Nov 20 13:21:07 +0000 [Node01: dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
[?] Sun Nov 20 13:21:07 +0000 [Node01: dsa_disc: ses.inconsistent.config:alert]: Inconsistent configuration detected for shelf connected to adapter 0b.

SAS-EXPANDER-MAP reports incorrect cabling.

  • The expander map does not show all shelves on both paths:

::> system node run -node <node_name> sasadmin expander_map

Expanders on channel 0a:
Level    1: WWN 500a0980085a5039, ID  1, Serial Number ' xxxxx', Product 'DS22412IOM12A   ', Rev '0270', Slot A

Expanders on channel 0b:
Level    1: WWN 500a09800e72633f, ID  0, Serial Number ' xxxxx', Product 'DS21212IOM12E   ', Rev '0230', Slot A
Level    2: WWN 500a0980085a50f5, ID  1, Serial Number ' xxxxx', Product 'DS22412IOM12A   ', Rev '0270', Slot B
Level    3: WWN 500a09800e72233f, ID  0, Serial Number ' xxxxx', Product 'DS21212IOM12E   ', Rev '0230', Slot B

  • Shelf 0 is not properly cabled

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.