Issue

The cluster reported intermittent alerts related to packet loss between cluster LIFs, including:

[vifmgr.cluscheck.droppedlarge:alert]: Partial packet loss when pinging from cluster LIF Node1_clus2 (node 1) to cluster LIF Node1_clus1 (node 2).
[vifmgr.cluscheck.droppedall:alert]: Total packet loss when pinging from cluster LIF Node1_clus2 (node 1) to cluster LIF Node1_clus1 (node 2).
[vifmgr.cluscheck.droppednone:notice]: No packet loss when pinging from cluster LIF Node1_clus2
(node 1) to cluster LIF Node1_clus1 (node 2).

Sw1:
Ethernet1/XX
transceiver is present
type is QSFP-40G-CSR4
name is CISCO-FINISAR
part number is FTL410QD4C-C1
revision is A
serial number is FIW253301AR
nominal bitrate is 10300 MBit/sec per channel
Link length supported for 50/125um OM2 fiber is 82 m
Link length supported for 50/125um OM3 fiber is 300 m
cisco id is 13
cisco extended id number is 16
cisco part number is 10-2837-03
cisco product id is QSFP-40G-CSR4
cisco version id is V03

Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.55 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -1.48 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.79 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:2 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.36 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -2.07 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -11.85 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:3 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.68 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -2.15 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.60 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning

Lane Number:4 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 29.69 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.30 V 3.63 V 2.97 V 3.46 V 3.10 V
Current 7.48 mA 15.00 mA 2.00 mA 14.00 mA 3.00 mA
Tx Power -1.99 dBm 2.99 dBm -11.30 dBm 0.00 dBm -7.30 dBm
Rx Power -10.55 dBm - 2.99 dBm -13.90 dBm 0.00 dBm -9.90 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------

Cluster port statistics showed zero errors, but switch interface diagnostics indicated input errors on ISL port Ethernet1/xx and port-channel1 on sw1, and output errors on interfaces connected to ports on multiple nodes.

Optical diagnostics revealed low receive optical power on Ethernet1/xx on one switch, close to warning threshold.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.