Issue
- EMS reports "
BATTERY (capacity low) CRITICAL
".
Example:
[NodeA:callhome.battery.failure:EMERGENCY]: Call home for BATTERY (capacity low) CRITICAL.
- Check
system sensors show
in SP, the status of battery is normal.
Example:
Bat_Status | 0x0 | discrete | Ready | na | na | na | na
Bat_Ambient_1 | 25.000 | degrees C | ok | 0.000 | 3.000 | 47.000 | 52.000
Bat_Ambient_2 | 25.000 | degrees C | ok | 0.000 | 3.000 | 47.000 | 52.000
Bat_Charge_Curr | 0.000 | Amps | ok | na | na | 5.500 | 6.000
Bat_Charge_Volt | 8.150 | Volts | ok | na | na | 8.350 | 8.400
Bat_Curr | 0.000 | Amps | ok | -0.100 | -0.050 | 2.500 | 3.000
Bat_Cycle_Count | 12.000 | cycles | ok | na | na | na | na
Bat_Design_Cap | 4.300 | Amps*hour | ok | 0.000 | 0.000 | 6.375 | 6.375
Bat_Dstg_Cycles | 12.000 | cycles | ok | 2.000 | 5.000 | na | na
Bat_Full_Cap | 3.025 | Amps*hour | ok | 2.000 | 2.200 | 4.750 | 5.000
Bat_Initial_Fcc | 3.275 | Amps*hour | ok | 2.000 | 2.200 | 4.750 | 5.000
Bat_Rem_Cap | 3.025 | Amps*hour | ok | 0.250 | 0.500 | 4.750 | 5.000
Bat_Temp | 24.000 | degrees C | ok | -5.000 | 0.000 | 55.000 | 60.000
Bat_Volt | 8.150 | Volts | ok | 6.000 | 6.500 | 8.300 | 8.500
- "
Learn cycle
" is recorded in "events all
" of SP.
Example:
Record 1552: Mon Feb 22 00:21:19.602467 2021 [IPMI.notice]: 7d04 | 02 | EVT: 6f08ffff | Bat_Status | Assertion Event, "Learn Cycle"
Record 1553: Mon Feb 22 01:31:20.286318 2021 [IPMI.notice]: 7e04 | 02 | EVT: ef08ffff | Bat_Status | Deassertion Event, "Learn Cycle"
- EMS reports "
nvram.battery.current.normal
"
Example:
[?] Thu Sep 02 06:17:01 UTC [NodeA: env_mgr: nvram.battery.current.normal:info]: The NVRAM battery current is normal.