CSHM: ClusterSwitchConfig_Alert: System health degraded due to wrong Cluster Switch cabling
Applies to
- ONTAP 9
- Cluster Switch Health Monitor (CSHM) AutoSupport message
Issue
- System health is degraded
cluster::>system health status show
Status
---------------
degraded
- Switch-Health subsystem is degraded
cluster::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
13 entries were displayed.
- The following health alerts are logged
cluster::> system health alert show
Node: node01
Resource: node01
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node01" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch02" is connected to the node "node01".
Node: node01
Resource: node02
Severity: Major
Indication Time: Mon Oct 07 13:19:08 2019
Suppress: false
Acknowledge: false
Probable Cause: One or more nodes are not connected to both cluster switches.
Possible Effect: If one cluster switch fails, "node02" might lose access to the cluster.
Corrective Actions: Ensure the switch "switch01" is connected to the node "node02".
2 entries were displayed.
4. You could also see the following heath alerts
cluster::> system health alert show
Node: cluster-01
Resource: Ethernet1/1
Severity: Minor
Indication Time: Wed Aug 25 05:23:27 2021
Suppress: false
Acknowledge: false
Probable Cause: MTU value "1500" on port "e0e" of node
"cluster-01" is improperly set. It
should be 9000.
Possible Effect: Received Ethernet packets that are larger than the
configured MTU are dropped, causing data transfer
issues.
Corrective Actions: modify the MTU using the command "network port
broadcast-domain modify -ipspace Cluster
-broadcast-domain Cluster -mtu <MTU>". To find out the
broadcast domain name of the port, execute the command
"network port broadcast-domain show".
5. AutoSupport reports:
HMSCSA:HA Group Notification from cluster1-03 (Health Monitor process cshm: ClusterSwitchConfig_Alert[cluster1-03]) ERROR