Issue

  • EMS reporting multiple errors about FANs
Mon Feb 20 09:42:57 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2
Mon Feb 20 09:42:57 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F1
Mon Feb 20 09:44:02 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F2
Mon Feb 20 09:44:27 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Mon Feb 20 09:44:42 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2
Mon Feb 20 10:42:40 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F1
Mon Feb 20 10:42:59 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan1 F2
Mon Feb 20 10:43:00 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F1
Mon Feb 20 10:44:06 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan2 F2
Mon Feb 20 10:44:30 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F1
Mon Feb 20 10:44:43 +0900 [node1: env_mgr: callhome.c.fan.fru.fault:error]: Call home for CHASSIS FAN FRU FAILED: SysFan3 F2

Mon Feb 20 09:00:00 +0900 [node1: statd: monitor.fan.failed:alert]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2.
Mon Feb 20 10:00:00 +0900 [node1: statd: monitor.fan.failed:alert]: Multiple fans has failed: Sysfan1 F1, Sysfan1 F2, Sysfan2 F1, Sysfan2 F2, Sysfan3 F1, Sysfan3 F2.
  • The fan status of the SP sensor is BAD
Sysfan3 F2                                 BAD
Sysfan3 F1                                 BAD
Sysfan2 F2                                 BAD
Sysfan2 F1                                 BAD
Sysfan1 F2                                 BAD
Sysfan1 F1                                 BAD
Chassis Thermal Zone                    OVER_TEMP
Thermal Shutdown                            UP
CPU0 Avg Critical                           NO
Temp Average Low                            NO
Temp Average High                           NO
CPU0 Temp Avg            normal           -65 C        --          --         -11 C        -1 C
InFlow Temp Avg          normal            25 C         0 C         5 C        50 C        55 C
OutFlow Temp Avg         normal            38 C         0 C         5 C        65 C        75 C
PCI Temp Avg             normal            34 C         0 C         5 C        60 C        70 C
Bat Temp Avg             normal            31 C         0 C         5 C        60 C        70 C
Amb2 Temp Avg            invalid           -- C         0 C         5 C        47 C        52 C
Amb1 Temp  Avg           invalid           -- C         0 C         5 C        47 C        52 C
PSU2 FRU Fan                                OK
PSU2 FRU Power                              ON
PSU1 FRU Fan                                OK
PSU1 FRU Power                              ON
Fan3 INFO                               FAILED
Fan2 INFO                               FAILED
Fan1 INFO                               FAILED
PSU1 INFO                               FRU_AVAIL
PSU1 INFO                               FRU_AVAIL
Fan1                                    MULTIFAULT
Fan2                                    MULTIFAULT
Fan3                                    MULTIFAULT
PSU1                                      GOOD

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.