Applies to

  • Baseboard Management Controller (BMC)
  • AFF A250
  • ONTAP 9

Issue

  • Updating BMC FW to 15.6, but it changed to 15.95P1 version, after when BMC reboot, it downgraded to 15.5P1.
  • Accessing with SP of a node in ssh, BMC console appears "Unable to open/create the Log File" message.

[12388 : 12388 INFO]Error sending Signal USR1 to  UART Logging application

[12388 : 12388 CRITICAL][uartlog.c:917]ERROR: Unable to open/create the Log File /var/sollog/SOLHostCapture.log::: No such file or directory
                    [12388 : 12388 CRITICAL][uartlog.c:111]ERROR: Unable to open/create the Log File /var/sollog/SOLHostCapture.log

  • Before BMC reboot:

Cluster::*> sp show

    IP           Firmware
Node          Type Status      Configured   Version   IP Address
------------- ---- -----------
------------ --------- -------------------------
node-01 BMC online   true         15.95P1   XX.XXX.XX.XXX
node-02 BMC unknown  true         15.95P1   XX.XXX.XX.XXX
2 entries were
displayed.

  • Rebooting the SP, SP has downgrades it to pre-update 15.5P1:

Cluster::*> sp show
                               IP           Firmware
Node
Type Status      Configured   Version   IP Address
------------- ---- ----------- ------------ ---------
-------------------------
node-01 BMC online   true         15.5P1    XX.XXX.XX.XXX
node-02 BMC online   true         15.5P1    XX.XXX.XX.XXX
2 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.