BMC networking changes at the LOADER are not persistent
Applies to
- AFF-C800
- ONTAP 9
Issue
- Example: Change the BMC IP from 10.1.1.34 to 10.1.1.56 via LOADER.
LOADER-A*> sp setup -d=0 -a=10.1.1.56 -n=255.255.255.0 -g=10.1.1.1
- Boot ONTAP into clustershell. After about 10 minutes the BMC IP will revert back to 10.1.1.34 rather than keeping 10.1.1.56.
::> system service-processor show
Node Type Status Configured Version IP Address
------------- ---- ----------- ------------ --------- -------------------------
node01 BMC online true 10.9P2 10.1.1.34
SP-DEBUG-MLOG-TXT.GZreports the BMC IP update to 10.1.1.34 during ONTAP boot.
2025-03-17 08:04:51.959 [sp_applications_init] [rlm_mgmt]: BEGIN - bmc_netconfig_if = 1
2025-03-17 08:04:52.425 [sp_applications_init] [none]: orftp_rcvr_from_rlm get file (/etc/rlm_config_to_filer) success, it took 0 seconds
2025-03-17 08:04:52.425 [sp_applications_init] [rlm_mgmt]: rlmp_parse_stats_file: buf is version 10.9P2
2025-03-17 08:04:52.425 [sp_applications_init] [rlm_mgmt]: rlmp_parse_stats_file: buf is ip 10.1.1.34
2025-03-17 08:04:52.425 [sp_applications_init] [rlm_mgmt]: rlmp_send_config: -- updating config