Applies to

  • FAS2750
  • BMC FW 11.6

Issue

Node down and cannot boot, and BMC/SP firmware cannot be updated: BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT

  • Controller re-seat does not solve  issue
  • BMC/SP boots, via console cable:
    • System unsuccessfully tries to update to FW 11.10, then restarts
  • Accesing BMC/SP via IP console:
    • System displays 11.6 and 11.2 as backup images via "Version"
    • Backup image is visible as loaded

 

  • Failure message visible from Loader:

Boot Loader version 6.0.17
Copyright (C) 2000-2003 Broadcom Corporation.
Portions Copyright (C) 2002-2023 NetApp, Inc. All Rights Reserved.
BIOS POST Failure(s) detected: SP IPMI failure. Abort AUTOBOOT
LOADER-A>

  • Continuous Syslog messages:

Dec  1 04:08:46 BMC env_mgr[2526]: isvc_send_request: 454: ISVCLIB command(4) rsp timed out
Dec  1 04:08:46 BMC env_mgr[2526]: SES page request returned error (2)
Dec  1 04:08:46 BMC env_mgr[2526]: Error opening ses, err -1
Dec  1 04:08:46 BMC env_mgr[2526]: cdev_reopen: error opening device 'ses', err -1.
Dec  1 04:08:46 BMC env_mgr[2526]: cdevices_poll_pending: cdev(2001) re-open, state is 4.
Dec  1 04:09:50 BMC env_mgr[2526]: isvc_send_request: 387: ISVCLIB received msg seq_id 1751 (expected 1807)

  • Repeated events:

Record 1455: Fri Dec 01 04:09:18.730000 2023 [ASUP.notice]: First notification email | (INVALID CHASSIS CONFIGURATION (Incompatible Partner PCM)) CRITICAL | Send failed

  • Output of storage failover hwassist show:

Warning: Unable to list entries on node <nodename>. RPC: Couldn't make
         connection [from mgwd on node "<nodename>" (VSID: -1) to mgwd at
         <ip-address>] 

Partner: <nodename>
Hwassist Enabled: -
Hwassist IP: -
Hwassist Port: -
Monitor Status: filer in takeover mode
Inactive Reason: -
Corrective Action: -
Keep-Alive Status: -

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.