Automatic shutdown sequence canceled
Applies to
- FAS8300
 - FAS8700
 - BMC FW 13.5
 
Issue
- System generates the following AutoSupport alert
 
Call home for BATTERY (wrong charge) WARNING.- The following messages can be seen in the EMS log
 
[Node-01: env_mgr: nvmem.battery.wrongCharge:alert]: The NVMEM battery charger is charging the battery even though the battery is not requesting to be charged. To prevent data loss, the system will shut down in 24 hours.
[Node-01: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (wrong charge) WARNING.
[Node-01: env_mgr: nvmem.battery.normalCharge:notice]: The NVMEM battery charging status is normal.
[Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.- BMC FW upgraded to 13.5  
    
- NVMEM battery messages no longer appear
 
 
- Following message is still logged:
 
Sun Aug 22 08:46:18 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 09:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.
Sun Aug 22 10:46:19 +0200 [Node-01: env_mgr: monitor.shutdown.cancel:notice]: Automatic shutdown sequence canceled.