Chassis power supply failure after a power outage
Applies to
- FAS/AFF Systems
- ONTAP 9
- Power Supply Unit (PSU)
- Power Distribution Unit (PDU)
Issue
- After a power outage, there is no power input to the system to boot the nodes.
- Amber LEDs are seen on the chassis power supplies.
- The power source to the PSUs is verified by connecting to an alternate PDU.
- Reseat of the power supplies does not bring them online.
EMS log
Tue Apr 09 11:49:00 1000 [node-nacl1-03: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Tue Apr 09 11:49:06 1000 [node-nacl1-03: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
Tue Apr 09 11:49:06 1000 [node-nacl1-03: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
::> system health alert show Node: node-nacl1-04 Alert ID: CriticalPSUFruOffAlert Resource: FFXW231xxxxx Severity: Critical Indication Time: Sun Nov 09 16:57:16 2025 Suppress: false Acknowledge: false Probable Cause: PSU1 is off. The nodes in this chassis are node-nacl1-06. Possible Effect: The system might switch off if the other redundant power supply units (PSUs) become faulty.Corrective Actions: 1. Check PSU1 and switch it on. 2. Refer to the Hardware specification guide for more information on the position of the power supply unit (PSU) and ways to check or replace it. 3. Contact support personnel if the alert persists.
STORAGE-FAULT section of AutoSupport
Enclosure Status: unrecoverableChannel: 0xShelf: 10Shelf Type: NS224NSM100Module Type: NSM100
Power Supplies:Element Status Status Bytes Status Descriptions1: OK 01,00,00,20 RQSTED ON2: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL