Chassis power supply failure after a power outage
Applies to
- FAS/AFF Systems
- ONTAP 9
- Power Supply Unit (PSU)
- Power Distribution Unit (PDU)
Issue
- After a power outage, there is no power input to the system to boot the nodes.
- Amber LEDs are seen on the chassis power supplies.
- The power source to the PSUs is verified by connecting to an alternate PDU.
- Reseat of the power supplies does not bring them online.
- For AFF-C400, following log entries may also appear:
Tue Apr 09 11:49:00 1000 [dc3ns-nacl1-03: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Tue Apr 09 11:49:06 1000 [dc3ns-nacl1-03: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0x. Check fans, power supplies, disks, and temperature sensors.
Tue Apr 09 11:49:06 1000 [dc3ns-nacl1-03: statd: callhome.shlf.fault:error]: Call home for SHELF_FAULT
Enclosure Status: unrecoverable
Channel: 0x
Shelf: 10
Shelf Type: NS224NSM100
Module Type: NSM100
Power Supplies:
Element Status Status Bytes Status Descriptions
1: OK 01,00,00,20 RQSTED ON
2: CRITICAL 02,00,00,F1 DC FAIL, OFF, RQSTED ON, FAIL