Aggregate in failed state due to missing drawer of DS460C shelf
Applies to
- ONTAP 9
 - DS460C Drawer
 
Issue
- Missing disks in a drawer would lead to an aggregate going offline.
 - FlexGroup volumes may go into an inconsistent state.
 - IOM Modules show OK status.
 - Drawer would be missing (no errors even reported) but disks for that drawer may be reported as faulty. Example:
 
::> system node run -node node_name -command storage show fault
No faults found in storage subsystem
::> system node run -node node_name -command storage show fault -v
Enclosure Status: normal
Channel: 0a
Shelf: 2
Shelf Type: DS460-12
Product Serial Number: SHABC0123456789
Module Type: IOM12
Disk Elements:
Element Status                  Status Bytes  Status Descriptions
  0 [Bay  0]: OK                01,00,00,38   BYPASSED A, DEVICE OFF, FAULT REQSTD
 (...)
 11 [Bay 11]: OK                01,0B,00,38   BYPASSED A, DEVICE OFF, FAULT REQSTD
 12 [Bay  0]: OK                01,00,00,00
 (...)
- Issue remains after drawer and snake cable re-seat.
 - Issue remains after IOM modules (one at a time) re-seat
 