AMBER light seen in front side of storage chassis
Applies to
- FAS/AFF
- ONTAP 9
Issue
- Amber attention LED is turned ON on the controller.
- No faults can be seen in the output of the
'system node environment sensors show'
command from the BMC. - Following warning is seen when we check '
system controller service-event show
'.
cluster::> system controller service-event show
Warning: Unable to list entries on node clus02-01. The Service Processor on
node "clus02-01" is not reachable. Verify that the SP or BMC is
online, verify that api-service is enabled on the SP or BMC, verify
that the partner node is running, check if pings from SP or BMC to
partner node work, check if hw-assist keep-alives are normal, check
that network ports are configured correctly and are functional (up).
Then, try the command again.
Unable to list entries on node clus02-02. The Service Processor on
node "clus02-02" is not reachable. Verify that the SP or BMC is
online, verify that api-service is enabled on the SP or BMC, verify
that the partner node is running, check if pings from SP or BMC to
partner node work, check if hw-assist keep-alives are normal, check
that network ports are configured correctly and are functional (up).
Then, try the command again.
- API-services are disabled.
cluster::> system service-processor api-service show
Service Processor API service configuration
Enabled: false
Port: 50000
Limit Access: true
Server Certificate: -internal-
Client Certificate: -internal-
CA Certificate: -internal-