Skip to main content
NetApp Knowledge Base

AFF A400 port errors on unused port with SFP

Views:
1,573
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

Applies to

  • AFF A400
  • 10/25 Gb/s network adapter
  • Unused ethernet ports

Issue

  • Sysconfig -A Port shows link up or flapping with SFP but no cable inserted:

slot 0: 10G/25G Ethernet Controller CX5-Mezz
e0e MAC Address: d0:22:ef:97:00:0d (auto-25g_sr-fd-up)
SFP Vendor: AVAGO
SFP Part Number: AFBR-725SMZ-NA1
SFP Serial Number: AD2016G02TZ

EMS logs

vifmgr.port.monitor.failed: The "link_flapping" health check for port e0e (node node-01) has failed. The port is operating in a degraded state.
 
  • CRC errors can be reported by the port:
EMS
[node-01: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0f on node node-01 is reporting a high number of observed hardware errors, possibly CRC errors.
 
  •  ifstat

    ::> system node run -node <node> -command ifstat -a

RECEIVE
Total frames:        0  | Frames/second:       0  | Total bytes:         0
Bytes/second:        0  | Total errors:    66920  | Errors/minute:       0
Total discards:      0  | Discards/minute:     0  | Multi/broadcast:     0
Non-primary u/c:     0  | Errored frames:      0  | Unsupported Op:      0
CRC errors:      66918  | Runt frames:         0  | Fragment:        66914

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 