"CHASSIS POWER DEGRADED: Power Supply Status Critical" alerts
Applies to
- ONTAP 9
- AFF A250 / AFF C250
- ASA A250 / ASA C250
Issue
- AFF-A250 node reports
CHASSIS POWER SUPPLY DEGRADED
andCHASSIS OVER TEMPERATURE
alerts. - PSU sensors unreadable in the node with the issue, but not by the partner. Example:
Event logs:
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 FB Hot is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Fan is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 In Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Warning is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 1 is degraded: PSU1 Out Fault is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Inlet is Unreadable
[n02: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Hot is Unreadable
[n02: power_low_monitor: monitor.chassisPower.degraded:alert]: Chassis power is degraded: Power Supply Status Critical: PSU2, PSU1.
[n02: power_low_monitor: callhome.chassis.power:error]: Call home for CHASSIS POWER DEGRADED: Power Supply Status Critical: PSU2, PSU1.
SP-LATEST-IPMI:
PSU1_Inlet | na | degrees C | na | na | 0.000 | 0.000 | 58.000 | 63.000 | na
PSU1_Hot | na | degrees C | na | na | 0.000 | 0.000 | 100.000 | 105.000 | na
PSU1_FB_Hot | na | degrees C | na | na | 0.000 | 0.000 | 100.000 | 105.000 | na
PSU1_Fan | na | RPM | na | na | 800.000 | 1200.000 | na | na | na
PSU1_status | na | discrete | na | na | na | na | na | na | na
PSU2_Inlet | na | degrees C | na | na | 0.000 | 0.000 | 58.000 | 63.000 | na
PSU2_Hot | na | degrees C | na | na | 0.000 | 0.000 | 100.000 | 105.000 | na
PSU2_FB_Hot | na | degrees C | na | na | 0.000 | 0.000 | 100.000 | 105.000 | na
PSU2_Fan | na | RPM | na | na | 800.000 | 1200.000 | na | na | na
PSU2_status | na | discrete | na | na | na | na | na | na | na