Issue

  • Node down due to L2 watchdog timeout after an ADR (Asynchronous DRAM Refresh) from events all log:

Record 392: Sat Feb 27 03:41:59 2021 [IPMI.critical]: ADR event ID: 0 at time: 1614397319
Record 393: Sat Feb 27 03:41:59 2021 [IPMI.critical]: ADR Battery destage cycles: 19
Record 394: Sat Feb 27 03:42:01 2021 [IPMI Event.critical]: NMI
Record 395: Sat Feb 27 03:42:01 2021 [IPMI.notice]: bd00 | 02 | EVT: 6fc824ff | System_Watchdog | Assertion Event, "Timer interrupt"
Record 396: Sat Feb 27 03:42:02 2021 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 397: Sat Feb 27 03:42:02 2021 [Trap Event.critical]: hwassist l2_watchdog_reset (29)
Record 398: Sat Feb 27 03:42:02 2021 [Trap Event.critical]: SNMP l2_watchdog_reset (29)
Record 399: Sat Feb 27 03:42:02 2021 [SysFW.notice]: ADR Timeout
Record 400: Sat Feb 27 03:42:02 2021 [SysFW.notice]: ADR Timeout
Record 401: Sat Feb 27 03:42:07 2021 [IPMI.notice]: be00 | 02 | EVT: 6fc104ff | System_Watchdog | Assertion Event, "Hard reset"
Record 402: Sat Feb 27 03:42:12 2021 [SP.critical]: Filer Reboots

or

Record 926: Sun Sep 29 22:50:42 2024 [IPMI.critical]: ADR event ID: 0 at time: 1727650242
Record 927: Sun Sep 29 22:50:42 2024 [IPMI.critical]: ADR Battery destage cycles: 18
Record 928: Sun Sep 29 22:50:43 2024 [IPMI Event.critical]: NMI
Record 929: Sun Sep 29 22:50:45 2024 [IPMI Event.critical]: L2 watchdog timeout hard reset
Record 930: Sun Sep 29 22:50:45 2024 [Trap Event.critical]: SNMP l2_watchdog_reset (29)
Record 931: Sun Sep 29 22:50:48 2024 [IPMI.notice]: 5301 | 02 | EVT: 6fc804ff | System_Watchdog | Assertion Event, "Timer interrupt"
Record 932: Sun Sep 29 22:50:48 2024 [IPMI.notice]: 5401 | 02 | EVT: 6fc104ff | System_Watchdog | Assertion Event, "Hard reset"
Record 933: Sun Sep 29 22:51:23 2024 [IPMI.notice]: 5501 | 02 | EVT: 0301ffff | Attn_Sensor1 | Assertion Event, "State Asserted"
Record 934: Sun Sep 29 22:52:15 2024 [IPMI Event.critical]: System reset
Record 935: Sun Sep 29 22:52:15 2024 [IPMI Event.critical]: L2 watchdog action completed
Record 936: Sun Sep 29 22:52:15 2024 [IPMI.notice]: L2 to L1 is 1(s) 142192(us)
Record 937: Sun Sep 29 22:52:32 2024 [SP.notice]: Delaying L2_WDOG ASUP email for 120 seconds
Record 938: Sun Sep 29 22:54:32 2024 [ASUP.notice]: First notification email | (REBOOT (watchdog reset)) CRITICAL | Send failed
Record 939: Sun Sep 29 23:02:49 2024 [SP.critical]: Heartbeat stopped

  • Node is in a reboot loop following an L2 watchdog timeout.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.