"ORPHAN DISK PROCESSING" detected after disk missing
Applies to
Issue
- Disk failed after multiple disk error:
[node01: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING
- After disk failed ONTAP recover the issued disk via power cycle and after recovery
ORPHAN DISK PROCESSING
notice detected.
Mon Sep 15 07:50:07 +0900 [node01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'Powercycle on device 0a.00.3 complete: status 0'}
Mon Sep 15 07:51:01 +0900 [node01: dmgr_thread: raid.disk.inserted:info]: Disk 0a.00.3 Shelf 0 Bay 3 [NETAPP X336_SCMNE04TA07 NA00] S/N [xxxxxx] UID [5000C500:D30B4843:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
Mon Sep 15 07:51:01 +0900 [node01: config_thread: raid.assim.disk.spare:notice]: Sparing Disk 0a.00.3P1 Shelf 0 Bay 3 [NETAPP X336_SCMNE04TA07 NA00] S/N [xxxxxxx] UID [6000C500:D30B4843:500A0981:00000001:00000000:00000000:00000000:00000000:00000000:00000000], because volume (vol1) is online and complete
Mon Sep 15 07:51:01 +0900 [node01: config_thread: callhome.disk.orphan:notice]: Call home for ORPHAN DISK PROCESSING.